What the engine behind this site can actually do, stated in three layers and counted live from the engine itself: 128 modules and 520 study switches in five engineering categories, every sub-category linked to the page where you can use it. Steady state is the mainstay, device- and event-level transients are included, and what is deliberately not done is listed as well.

engine modules
128
study switches
520
engineering categories
5
tool entries on site
72

Start from your task

Six jobs engineers come here to do

Each card below is one job. Open it to see the source-container → route mapping behind the count. Browsing by capability domain is kept further down this page.

J1

Will my design pass the review?

Selection, plus the steady-state studies that back an approval review.

29 routes
J2

Is my grid connection compliant?

Only one live entry point on the whole site today; the grid-compliance evidence pack is still to be wired.

2 routes
J3

How do I prove this option is the best?

Parameter sweep and scheme comparison are live; the pareto-optimisation, design-optimiser and sensitivity engines have no standalone entry point yet.

5 routes
J4

How long will my equipment last, and which unit should I replace?

Only one live entry point on the whole site — and this is the only recurring, paid use case.

1 routes
J5

How will it run across a year, and how much will it earn?

Applies to both distribution and PV-plus-storage. Distribution side: load, losses and demand charges. PV-plus-storage side: generation, storage and payback.

8 routes
J6

Where do the drawings, reports, lists and compliance packs come from?

Cross-cutting: the drawings, reports and deliverables of J1–J5 all land here.

19 routes
How this list is defined

The simulation and sizing capabilities on this site come from the power-system engine used internally byQDTB, the engine that QDTB's engineering department uses as a simulation tool to guide the production of electrical equipment. Limited by the hardware capacity and computing cost of a web server, this site exposes only part of the engine's capabilities. The table below groups every module and study switch into five engineering categories, and each sub-category links straight into the page where you can use it — this is a “what it can do” overview, not a marketing page. Capability is stated in three layers, none of them hidden: (1) steady-state calculation is the mainstay — load flow, short circuit, voltage drop, sizing and withstand checks; (2) on top of it the engine solves device- and event-level transients and quasi-steady sequences — transformer magnetisation inrush, series-reactor fault di/dt with core saturation, short-circuit DC-component decay, bus transfer, auto-reclosing, PV low-voltage ride-through and converter average models; (3) what is deliberately not done is listed as well — no system-wide EMT phase-by-phase simulation (PSCAD/EMTP class), no full electromechanical generator swing / rotor-angle stability process, and no numeric waveform simulation of switching or lightning overvoltages.

Capability in three layers

The same three layers are stated in the FAQ, in About US and here — one source of truth, nothing hidden.

01

Steady state — the mainstay

A real network solution, not a table lookup: load flow, IEC 60909 short circuit (three-phase, two-phase, two-phase to earth, single-phase to earth), voltage drop, equipment sizing and withstand checks, reactive compensation.

02

Time series & quasi-steady

Time-series load flow, PV time series, unbalanced time series, BESS state of charge, quasi-static controllers, Volt-VAR optimisation and N-1 transfer studies.

03

Device- and event-level transients

Series-reactor fault di/dt with core saturation, transformer magnetisation inrush, short-circuit DC-component decay, bus transfer, auto-reclosing, PV low-voltage ride-through and converter average models / VFD.

Every chip opens the page where that capability is usable.

Deliberately not done

Full system-wide EMT phase-by-phase simulation · the full electromechanical generator swing (rotor-angle) process · numeric waveforms for switching or lightning overvoltages · seconds-to-minutes phase-by-phase time-domain simulation.

Voltage stability is offered as a static margin — continuation power flow gives the P–V nose curve, the critical point and the weakest bus — not as a time-domain stability simulation. Voltage stability (continuation power flow) →

Read the full statement in the FAQ →

Recently added and already live

Auto-reclosing, voltage stability, protection setting / sequence check and DC short circuit are wired to real engine modules and are open now. Each one is a page you can run, not a capability statement.

The site tool index further down is the shared entry point for all of them, whether or not a page is in the left navigation yet.

Engine capability totals

engine modules 128 · study switches 520

Fig · Capability distribution by category (modules / switches)

By module count

Design & Selection20
Simulation & Analysis82
DER & Microgrid13
Economics & Optimization3
Delivery & Compliance10

By study-switch count

Design & Selection61
Simulation & Analysis325
DER & Microgrid70
Economics & Optimization19
Delivery & Compliance45

Counts are computed live from the generated engine scan — they are never typed into this page.

Capability tree (click to expand; a sub-category links straight to its page)

Site tool index

72 tool entries indexed

Read live from the generated capability data, which is itself produced by scanning the engine sources and the site navigation — nothing here is typed in by hand. Each entry opens the page directly.

Engine-wired pages not yet in the left navigation· 1

Where to go next