Nameplate and system data entered by you.
Reactive compensation & filter design — bank sizing, tuned branches, anti-resonance check
Enter the load, the transformer and the harmonic background: you get the reactive compensation in standard kVAR steps, the resulting power factor and loss reduction, the automatically selected filter branches (tuning order, kVAR, C/L/R) and the anti-resonance check. The scope is a 0.4 kV LV bus — the engine's harmonic injection and branch-capacity basis in this tool is calibrated at 0.4 kV.
Method
This tool covers the 0.4 kV LV bus end to end. For 6/10 kV the engine's branch-capacity basis would need re-calibration, so no converted value is shown.
Input sources
Formulas and limits come from the stated standard.
Inputs & calculation
Fill the three groups — load & system, harmonic background, compensation & filter — then press Calculate.
① Load & system
Required
kV
Required
kVA
Required
%
Required
kW
Required
Recommended
Required
This tool covers the 0.4 kV LV bus end to end. For 6/10 kV the engine's branch-capacity basis would need re-calibration, so no converted value is shown.
The resonance scan uses an assumed upstream short-circuit power of 100 MVA (the engine needs grid stiffness). Resonance order and amplification change with it — enter the real value on the scheme page.
② Harmonic background
Required
Recommended
%
Recommended
%
Recommended
%
Recommended
%
Recommended
%
Required
③ Compensation & filter
Recommended
kvar
Recommended
%
Required
Required fields complete — ready to run.
Results
Frequently asked questions
- What can this calculator do?
- Enter the load, the transformer and the harmonic background. The designer sizes the reactive compensation bank in standard kVAR steps from Qc = P·(tan φ1 − tan φ2) and returns the resulting power factor and loss reduction, automatically selects the detuned filter branches (tuning order, kVAR and the C/L/R values) and runs the anti-resonance check, with an impedance–frequency scan chart. Typical uses: compensating a 0.4 kV LV bus to a target power factor, deciding whether plain capacitors are safe or detuned branches are required, and documenting the choice against the harmonic limits. The scope is a 0.4 kV LV bus — the engine's harmonic-injection and branch-capacity basis is calibrated there.
- How is the bank sized and the filter tuned?
- The compensation follows Qc = P·(tan φ1 − tan φ2), rounded up to the standard bank list. Harmonic limits come from GB/T 14549-1993 / IEEE Std 519-2022 / IEC 61000-2-2 / EREC G5/5 through the single source the harmonic-limits engine. The branch tuning follows h_r = n·(1 − 6%) with the reactance ratio p = 1/h_r² and R = Xc/(h_r·Q). The filter design is an engineering approximation and is not claimed to be optimal.
- What does the anti-resonance check tell me?
- It finds the frequencies at which the capacitor bank in parallel with the supply inductance amplifies harmonics — analytically h = √(Ssc/Qc) and 1/√p, then refined on a 50 Hz coarse grid taken down to 5 Hz — so you can see whether a harmonic already present in the background sits on a resonant peak. That is the fact that decides between a plain bank and a detuned one.